HR 1251W F2 is specially designed for high efficient discharge application. Its characteristics are small volume, light weight and high discharge efficiency. It can be used for more than 260 cycles at 100% discharge in cycle service, or three to five yeas in standby service.
CSB Batteries can be stored for more than 6 months at 25°C (77°F) Please charge batteries before using. For higher temperatures the time interval will be shorter.
Terminal
F1/F2-Faston Tab187/250
Container Material
ABS(UL94-HB/FileE50263)*Flammability resistance of(UL94-V0/File E54297) can be available upon request.
Dimensions
Constant
Current Discharge Characteristics Unit:Amperes (25°C,77°F)
F.V/Time
2MIN
4MIN
6MIN
8MIN
10MIN
15MIN
20MIN
30MIN
60MIN
90MIN
1.60V
85.83
64.00
50.75
42.96
36.75
27.08
21.42
15.42
8.33
6.65
1.67V
82.40
61.64
49.18
41.77
35.81
26.71
20.89
15.30
8.29
6.60
1.70V
80.51
60.47
47.97
41.16
35.23
26.35
20.66
15.22
8.27
6.58
1.75V
77.21
57.91
46.37
39.91
34.27
25.73
20.34
15.10
8.24
6.52
1.80V
72.92
54.75
44.63
38.33
32.85
24.83
19.92
14.92
8.20
6.44
1.85V
68.63
51.58
42.74
36.52
31.55
23.87
19.59
14.71
8.16
6.36
Constant
Power Discharge Characteristics Unit:Watts (25°C,77°F)